Description
Specification | |||
No. | Item | General Parameter | Remark |
1 | Combination method | 16S4P | |
2 | Rated Capacity | 400Ah | Standard discharge after Standard charge(package) |
3 | Factory Voltage | 51.2V | Mean Operation Voltage |
4 | Voltage at end of Discharge | 46V | Discharge Cut-off Voltage |
5 | Charging Voltage | 56V | Charge Cut-off Voltage |
6 | Internal Impedance | ≤60mΩ | Internal resistance measured at AC 1KH Z after 50% charge The measure must uses the
new batteries that within one week after shipment and cycles less than 5 times |
7 | Standard charge | Constant Current 100A
Constant Voltage see No.5 |
Charge time : Approx 2.5h |
8 | Maximum Charge | 150A | |
9 | Standard discharge | Constant current:100A
end voltage see NO.4 |
|
10 | Maximum Continuous Discharge Current |
200A | 200A when T≥10ºC 100A when 0ºC>T≥-20ºC |
11 | Operation Temperature Range |
Charge: 0~45℃ | 60±25%R.H.Bare Cell |
Discharge: -20~55℃ | |||
12 | Storage Temperature Range |
Less than 12 months : -10~35℃ | 60±25%R.H.at the shipment state |
Less than 3 months: -10~45℃ | |||
Less than 7 day : -20~65℃ | |||
13 | Dimensions | (L*W*H) 600*280*1620mm | Include Bracket |
14 | Weight | Approx :235.5kg | |
15 | BMS Port | CANBUS/RS485 | |
16 | BMS Support | 15PCS Parallel connection | 300KWH at max |